12
Vermont Castings, Majestic Products, 360DVS Series
10002547
Your fireplace is approved to be vented either through
the side wall, or vertically through the roof.
• Only Vermont Castings, Majestic Products venting
components, specifically approved and labeled for
this fireplace, may be used.
• Venting terminals shall not be recessed into a wall
or siding.
• Horizontal venting must be installed on a level
plane without an inclining or declining slope.
There must not be any obstruction such
as bushes, garden shed, fencing, deck
or utility building within 24” (610 mm)
from the front of the termination hood.
Do not locate the termination hood
where excessive snow or ice buildup
may occur. Be sure to check the vent
termination area after snow falls; clear it
to prevent accidental blockage of the
venting system. When using a snow
blower, make sure snow is not directed
toward the vent termination area.
Location of Vent Termination
NOTE: It is imperative the vent termination be
located observing minimum clearances
as shown on the following page.
General Venting
Fig. 12 Honeywell Ignition Module.
This appliance may be fitted with a Honeywell ignition
module.
Installation of the remote ON/OFF starter switch on
electronic ignition units (Fig. 12):
1. Thread the wiring through the holes on the side
panels of the appliance. Take care not to cut the
wire or insulation on metal edges. Route the wire to
a conveniently located receptacle box.
2. Attach the wire to the ON/OFF switch and install
the switch into the receptacle box.
3. Connect the white wire from the wall switch to the
black wire from the transformer, using an approved
wire nut. Connect the black wire from the wall
switch to the black wire running from the #6
position of the ignition module, also using an
approved wire nut.
Electronic Gas Control Valve
PILOT
HONEYWELL IGNITION MODULE
BLUE
BLACK
WHITE
NOVA SIT 822 VALVE
HI
LO
POWER CORD
W/FEMALE SPADE
120 VAC RTN
WHITE
GREEN
BLACK
120 VAC HOT
BLACK
YELLOW
24 VAC RET
40VA TRANSFORMER
24 VAC HOT
BLACK
WHITE
WALL SWITCH
WHITE
OFF
1 2 3
4 5 6 8 9
MV MV/VP PV GRD 24V SENSE SPARK
24V
ORANGE
RED
GREEN
ORANGE
Honeywell_wiring